RETIRED ›
This product is no longer available and has been replaced by: 05103-L. Some accessories, replacement parts, or services may still be available.
05103-LC Wind Monitor for CS110 or MetData1
Services Available
Calibration No

Overview

The 05103, manufactured by R. M. Young, measures wind speed with a helicoid-shaped, four-blade propeller. Wind direction is sensed by the orientation of the fuselage-shaped sensor body, which is connected to an internal potentiometer.

Read More

Images

Related Products

Technical Description

The 05103 Wind Monitor is made out of rigid UV-stabilized thermoplastic with stainless steel and anodized aluminum fittings. The thermoplastic material resists corrosion from sea air environments and atmospheric pollutants. It uses stainless-steel precision-grade ball bearings for the propeller shaft and vertical shaft bearings.

The 05103 measures wind speed with a helicoid-shaped, four-blade propeller. Rotation of the propeller produces an ac sine wave that has a frequency directly proportional to wind speed. The ac signal is induced in a transducer coil by a six-pole magnet mounted on the propeller shaft. The coil resides on the non-rotating central portion of the main mounting assembly, eliminating the need for slip rings and brushes.

Wind direction is sensed by the orientation of the fuselage-shaped sensor body, which is connected to an internal potentiometer. The datalogger applies a known precision excitation voltage to the potentiometer element. The output is an analog voltage signal directly proportional to the azimuth angle.

Specifications

Operating Temperature Range -50° to +50°C (assuming non-riming conditions)
Mounting Pipe Description
  • 34 mm (1.34 in.) OD
  • Standard 1.0-in. IPS schedule 40
Main Housing Diameter 5 cm (2.0 in.)
Propeller Diameter 18 cm (7.1 in.)
Overall Height 37 cm (14.6 in.)
Overall Length 55 cm (21.7 in.)
Weight 1.5 kg (3.2 lb)

Wind Speed

Range 0 to 100 m/s (0 to 224 mph)
Accuracy ±0.3 m/s (0.6 mph) or 1% of reading
Starting Threshold 1.0 m/s (2.2 mph)
Distance Constant 2.7 m (8.9 ft) 63% recovery
Output ac voltage (three pulses per revolution)

90 Hz (1800 rpm) = 8.8 m/s (19.7 mph)

Wind Direction

Mechanical Range 0 to 360°
Electrical Range 355° (5° open)
Accuracy ±3°
Starting Threshold 1.1 m/s (2.4 mph) at 10° displacement
Damping Ratio 0.3
Damped Natural Wavelength 7.4 m (24.3 ft)
Undamped Natural Wavelength 7.2 m (23.6 ft)
Output
  • Analog dc voltage from potentiometer (resistance 10 kohm)
  • Linearity is 0.25%.
  • Life expectancy is 50 million revolutions.
Voltage Power switched excitation voltage supplied by data logger

Related FAQs

Number of FAQs related to 05103-LC: 4

Expand AllCollapse All

  1. The information included on a calibration sheet differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a datalogger. For other sensors, the calibration sheet is a pass/fail report.

  2. This depends on the information contained in the calibration sheet:

    • If the calibration sheet contains coefficient information, Campbell Scientific keeps a copy, and a replacement copy can be requested.
    • If the calibration sheet does not contain coefficients, Campbell Scientific does not keep a copy. It may be possible to contact the original manufacturer for a replacement copy.
  3. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field on the product’s Ordering tab. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  4. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a datalogger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact an application engineer at Campbell Scientific for assistance.